<ErrorNumber>7004</ErrorNumber>
<ErrorFamily>Carriage</ErrorFamily>
<ErrorMessage>
CARRIAGE: unexpectedly arrived at AWAY position - image size may have been too large
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The carriage AWAY switch was tripped unexpectedly. This can happen if the carriage
stalls when moving towards the HOME switch, or if the image data sent from the
workstation is incorrectly sized or positioned with respect to the actual plate size.  This
error is also reported if the "carriage move" command moves the carriage to the AWAY
switch.
</text></DescriptionText>
<DescriptionText><text>
If this error is occurs while imaging, the likely cause is incorrectly sized or positioned
image data.  Check that the actual plate size matches the plate size entered at the
workstation.  Also check that the start of the image has not been offset by workstation or
NVS parameters.  The following NVS parameters should be checked:
</text></DescriptionText>
<DescriptionText><text>
"set gc sss", check with integrators for correct setting
</text></DescriptionText>
<DescriptionText><text>
"set gc sssa", check with integrators for correct setting
</text></DescriptionText>
<DescriptionText><text>
"set mode &lt;N&gt; sssa", which should normally be 0.
</text></DescriptionText>
<DescriptionText><text>
It is also possible that the carriage stalled while performing asynchronous retraces (when
waiting for the RIP).  The imaged plate should be inspected for artifacts.  Look for dark
bands where the carriage stalled, or places where the image is "compressed".  Another
image can be attempted, preferably one with many asynchronous retraces, and the
leadscrew watched.  Watch particularily where the carriage starts and stops while it waits
for the RIP.  If any stalling is detected, check the leadscrew for binding and the
leadscrew hanger for alignment.  Also check the following NVS parameters for correct
settings:
</text></DescriptionText>
<DescriptionText><text>
"set carriage pgain"
</text></DescriptionText>
<DescriptionText><text>
"set carriage mgain"
</text></DescriptionText>
<DescriptionText><text>
"set carriage again"
</text></DescriptionText>
<DescriptionText><text>
These can be temporarily increased from their factory settings if it helps the problem.
However this may lead to over-heating the carriage motor so the real cause of the
problem should be found.
</text></DescriptionText>
<DescriptionText><text>
If there is no problem detected with the leadscrew or NVS parameters, the motor or ALE
may be at fault.  However, check the carriage drive voltages (all carriage drives currently
use 80VDC) before swapping these.
</text></DescriptionText>
<DescriptionText><text>
If this error occured while the carriage was moving in the "home" direction (like when
imaging, etc) or the carriage stopped along way from AWAY, suspect that a false
AWAY signal caused the error.  This is likely due to either a foreign object tripping the
AWAY switch, a faulty HOME/AWAY board, or a faulty or loose HA-BP cable.  Check
for any slip sheets, loose head wires, cable ties, etc in the vicinity of the HOME/AWAY
board.  If none are detected, move the carriage back and forth ("carriage away" or "x"
and then "carriage home" or "w") to see if the error can be replicated by flexing the cable
track.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Click on CANCEL (if it's available) or RESUME, since the Platesetter should recover
automatically from this error. Check the plate(s) imaged around the time of this error
carefully for artifacts.  In any case, record the error message and call Creo Service for
help as the machine probably needs servicing.
</text></DescriptionText>
</OperatorAction>
<Cause>
carriage stalled while moving in the "home" direction (possibly when imaging)
</Cause>
<Cause>
faulty HOME/AWAY board or cable causing false signals
</Cause>
<Cause>
foriegn object (such as a cable or slipsheet) tripping AWAY switch
</Cause>
<Cause>
incorrectly set NVS parameter"set mode &lt;N&gt; sssa"
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:28 2008 PST
</Updated>
<Links>
</Links>
</Error>